0 Cookie Img

High Voltage Thermal Resistor Soft Starter

High Voltage Thermal Resistor Soft Starter
High Voltage Thermal Resistor Soft Starter
Product Code : 10
Price And Quantity
Minimum Order Quantity :
1
Unit of Measure :
set
Product Specifications
Output Voltage :
3300/11000 Volt (V)
Product Type :
Thermal Resistor Soft Starter
Frequency (MHz) :
50/60 Hertz (HZ)
Input Voltage :
3300-11000 Volt (V)
Phase :
Three Phase
Product Description

Working from 1993, we are the promising manufacturer and exporters of High Voltage Thermal Resistor Soft Starter. It is required for managing the performance of different types of machines including conveyors and other AC motor based devices. The resistance in this starter is disconnected when motor reaches to its stable or full speed form. High Voltage Thermal Resistor Soft Starter is used for preventing machine damage due to high and sudden variations of electrical power & voltage by limiting initial supply of current.

Features:

  • Suitable for high voltage applications in power plants

  • Decreases electrodynamic stress

  • Energy efficient nature

Technical Details:


Table 1 Performance characteristic list of HTR3\HTR4\HTR6 series HTR




Sequence number

Performance and configuration

HTR3 series

HTR4 series

HTR6 series

1

Constant current soft start

√

√

√

2

Low voltage drop when start

√

√

√

3

High power factor when start

√

√

√

4

Safe(resistance changes in static state)

√

√

√

5

Trouble-free, Maintenance-free

√

√

√

6

Liquid level detection

√

√

√

7

Infrared temperature measurement

√

√

√

8

Adjustable initial resistance value


√

√

9

Main material of electrode

Cu\Ni

√

√

√

Ti



√

10

Environmental temperature on the impact of the initial resistance <2%


√

√

11

PLC control


√

√

12

Service life >30 years



√

13

Completely sealed



√

14

Applicable to harsh environment



√

15

Communication interface(RS232,RS485)



√

16

HMI



√

17

Dynamic liquid display



√


Note: The above functions and configuration for reference purposes only, different systems may have some changes




Table 2 Main technical data HTR3-500~22000








Type

Applicative power of motor
(kW)

Starting current range

Continual start times

Temperature rise for every start<ºC

Outline dimension(Width ×Length× Height)
A×B×H

Net weight (ton)

Weight after
resistor
configuration

HTR3-500

≤500

2.0-3.5Ie

Working condition

10

1600×1200×2300

1.7

2.6

HTR3-1000

500~1000




1600×1200×2300

1.9

3.0

HTR3-1600

1000~1600




1800×1200×2300

2.05

3.6

HTR3-2000

1600~2000




2000×1200×2300

2.2

4.0

HTR3-2500

2000~2500




2200×1600×2300

2.5

5.4

HTR3-3200

2500~3200




3300×1600×2300

3.0

6.6

HTR3-4500

3200~4500




3600×1600×2300

3.8

8.6

HTR3-6000

4500~6000




4200×1600×2300

4.5

10.2

HTR3-8000

6000~8000




4500×1600×2650

4.7

11.5

HTR3-10000

8000~10000




4800×1600×2650

5.0

13.0

HTR3-15000

10000~15000




5400×1800×2650

7.0

17.0

HTR3-22000

15000~22000




6000×1800×2650

8.6

21.5

Table 3 Main technical data HTR4-500~22000








Type

Applicative power of motor
(kW)

Starting current range

Continual start times

Temperature rise for every start<ºC

Outline dimension(Width ×Length× Height)
A×B×H

Net weight (ton)

Weight after
resistor
configuration

Remark

HTR4-500

≤500

2.0-3.5Ie

Working condition

10

1600×1200×2650

2.2

3.1

See
Table
3

HTR4-1000

500~1000

1600×1200×2650

2.4

3.6

HTR4-1600

1000~1600

1800×1200×2650

2.6

4.2

HTR4-2000

1600~2000

2000×1200×2650

2.8

4.8

HTR4-2500

2000~2500

2200×1600×2650

3.0

5.4

HTR4-3200

2500~3200

3300×1600×2650

3.1

6.6

See
table
4

HTR4-4500

3200~4500

3600×1600×2650

3.8

8.6

HTR4-6000

4500~6000

4200×1600×2650

4.5

10.2

HTR4-8000

6000~8000

4500×1600×2650

4.7

11.5

HTR4-10000

8000~10000

4800×1600×2650

5.0

13.0

HTR4-15000

10000~15000

5400×1800×2650

7.0

17.0

HTR4-22000

15000~22000

6000×1800×2650

9.0

21.5

Type

Applicative power of motor
(kW)

Starting current range

Continual start times

Temperature rise for every start<

Outline dimension(Width ×Length× Height)
A×B×H

Net weight (ton)

Weight after
resistor
configuration

Remark

HTR6-500

≤500

2.0-3.5Ie

Working condition

10

1800×1600×2650

2.2

3.1

See
table
5

HTR6-1000

500~1000

10

1800×1600×2650

2.4

3.6

HTR6-1600

1000~1600

10

1800×1600×2750

2.6

4.2

HTR6-2000

1600~2000

10

1800×1600×2750

2.8

5.3

HTR6-2500

2000~2500

10

3300×1600×2800

3.1

6.6

HTR6-3200

2500~3200

10

3300×1600×2800

4.0

7.2

HTR6-4500

3200~4500

8

4200×1600×2800

5.0

8.6

HTR6-6000

4500~6000

8

4200×1600×2800

6.0

11.7

HTR6-10000

6000~10000

8

4800×1600×2800

7.0

14.6

HTR6-15000

10000~15000

8

5700×2000×2800

8.5

18.8

HTR6-22000

15000~22000

8

6000×2000×2800

10.7

24.5

HTR6-32000

22000~32000

8

9000×2000×2800

15.1

36.0

HTR6-45000

32000~45000

8

10800×2000×2800

20.1

51.0

Contact Us